Airsoft Canada
https://www.replicaairguns.ca/airsoft

Go Back   Airsoft Canada > Discussion > Doctor's Corner
Home Forums Register Gallery FAQ Calendar
Retailers Community News/Info International Retailers IRC Today's Posts

Glock help please!

:

Doctor's Corner

Reply
 
Thread Tools
Old August 31st, 2009, 17:07   #16
MikeMcNair
 
Join Date: May 2009
Location: PA
Send a message via AIM to MikeMcNair
yeah, that is a pain in the ass. just take your time. put hammer spring on hammer, hammer in 93, and slide in the spacer, then the pin.

use an allen key if it helps you hold the parts in place before sliding in the pin (76)
MikeMcNair is offline   Reply With Quote
Old August 31st, 2009, 21:00   #17
CDN_Stalker
Official ASC Bladesmith
 
CDN_Stalker's Avatar
 
Join Date: Jul 2003
Location: Ottawa, Ont.
Send a message via MSN to CDN_Stalker
I find it WAY easier to not put tension on the hammer spring until you have the hammer assembly back together. Just let the tail of the spring hang down, position all the parts and try to keep the striker in place, put the pin though, then lift the hammer spring tail up and plop on the ledge. Might have to bend the corner of the ledge a bit to fit the spring through, but it works like a charm, with the added benefit of having that hook on the ledge keeping the spring tail in place.
CDN_Stalker is offline   Reply With Quote
Old September 4th, 2009, 02:49   #18
unsavory
 
unsavory's Avatar
 
Join Date: Jul 2009
Dear all, finally managed to reassemble the hammer assembly after several frustrating tries. Problem is, its still messed up and wont fire! Worse now in fact! I noticed the striker isnt hitting the gas release button hard enough to release the gas from the mag. Weak hammer spring perhaps?

Relay arm misalingment seems to be out of the window now, since the relay arm is snug and in perfect contact with its parts.








Quote:
Originally Posted by CJay View Post
easy test bud - if u press on the right side of the rear of the slide and pull the trigger and it fires fine then the relay arm is off or misaligned. have the same problem with a KSC G27 a while back - bought a new arm and fixed problem instantaneouly - even when i compare the arm to the new one I can't see any difference but one won't connect properly without exherting pressure on the rear right of the slide assembly!

Thanks for the tip, tried doing what you said, but it still didnt work. So it could be something else.
unsavory is offline   Reply With Quote
Old September 4th, 2009, 02:53   #19
Skladfin
 
Skladfin's Avatar
 
Join Date: Dec 2006
Location: Glace Bay, Nova Scotia
you sure its not just an empty propane tank?
Skladfin is offline   Reply With Quote
Old September 5th, 2009, 00:51   #20
unsavory
 
unsavory's Avatar
 
Join Date: Jul 2009
Quote:
Originally Posted by Skladfin View Post
you sure its not just an empty propane tank?
Haha the propane tank isn't empty. pretty sure.

Last edited by unsavory; September 5th, 2009 at 00:54..
unsavory is offline   Reply With Quote
ReplyTop


Go Back   Airsoft Canada > Discussion > Doctor's Corner

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


Airsoft Canada
https://www.replicaairguns.ca/airsoft

All times are GMT -4. The time now is 16:37.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.